APS CAT 7A F/UTP INDOOR 4P
Design
Conductor: solid bare copper AWG23/1 Insulation: Cellular polyolefin (SFS-PE), nominal Ø 1.38 mm Pair: No 2 insulated conductors stranded together into a pair Colour code: 1. White/blue 2.White/orange 3. White/green 4. White/brown (IEC 708-1) Screen 1: Aluminium/polyester or Aluminium/polyester/aluminium tape over each single pair Screen 2: overall Tinned Copper Wire Braid Outer jacket: Grey Fire Retardant and UV Resistant SHF2 material, LSZH Marking : APS Finland – ww/yy – S/FTP 4x2xAWG23/1 Cat.7 LSZH SHF2 – IEC60332-3-22 Cat A – lot + mEnvironmental properties and Fire Performances
Degree of acidity of gases: IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10μS/mm) Halogen acid gas: IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%) Smoke Emission: IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%) Toxicity of evolved gas: EN50305 9.2 Flame retardant : IEC 60332-1-2 Fire retardant : IEC 60332-3-22 Cat.A Ozone resistant: IEC60811-2-1, DIN VDE 0472 part 805 B LSZH SHF2 : IEC 60092-360 Oil resistant: IEC60811 Water absorption: IEC60811-1-3 UV resistant: IEC60811-2-1, ASTM-D-2565-92A Cold bend & impact : CSA C22.2, UL44Electrical characteristics (IEC 60811, EN 50288-4-2)
Test voltage: 0.7kV a.c. for 1 minute Resistance of the conductor @ 20°C : ≤ 14,5 /100m Insulation resistance : ≥ 500 MΩxkm (100V-500V) Nominal Capacitance @ 800÷1000MHz : 45 pF/m Average characteristic impedance: 100 ± 15 Ω @ 1-100MHz Transfer impedance : ≤ 3mΩ/m @ 10MHzc19-c20 Power Cable
c19-c20 Power Cable
Key features;- Connects high-output devices with C19/C20 power connectors, blade server chassis.
- Thick 12 AWG wire gauge manages high power levels
- C20 Male to C19 Female 250V 16A is perfect for supplying power to network devices that require a heavy-gauge power cord, such as servers, routers, network switches and blade server enclosures.
- Featuring a C19 connector on one end and a C20 connector on the other, this cable provides a reliable power connection from a PDU or UPS to your equipment.
- Connect the C19 receptacle to your network device and plug the C20 connector into a PDU or UPS outlet.
- The P036-010-16A is manufactured using superior materials for reliable performance. The high-quality connectors are molded for durability and have integral strain-relief for a secure connection.
- Additionally C19 to c20 cable has three 14 AWG conductors and a 16-amp rating for cooler operation.
Data Cable oraimo OCD-L32
Fibre cable Outdoor 4 Core Singlemode SM Per Metre
Fibre cable Outdoor 4 Core Singlemode SM Per Metre
Key features;- Core Count: This cable has 4 fiber optic cores. Each core can transmit data independently, providing multiple data channels for various applications.
- Single-Mode: Single-mode fibers are designed for long-distance data transmission and offer low signal attenuation, making them suitable for high-speed and high-bandwidth applications over extended distances.
- OS2:. It is optimized for long-haul data transmission and is commonly used for applications such as high-speed data networks, telecommunication systems, and internet backbone infrastructure. OS2 fibers have a core size of 9 microns.
- Outdoor Use: IT can withstand exposure to environmental factors such as UV radiation, moisture, and temperature variations. It is suitable for outdoor networking applications where long-distance connectivity is required.
- Meter-Based Pricing: Like other fiber optic cables, this cable is typically sold per meter, allowing you to purchase the exact length you need for your outdoor installation. Meter-based pricing offers flexibility and cost-effectiveness for custom cable lengths.
- Applications: Is ideal for applications that demand high-speed and long-distance data transmission , such as connecting buildings across a large campus, establishing communication links between remote locations, or providing high-capacity data connectivity for outdoor network equipment.
Giganet 1U Cable Manager
Giganet 2U cable Manager closed
Giganet Cat 6A 1M FTP patchcord
Key features;
HDPE insulation over conductors and PVC jacket
Unshielded 4 pair twisted multi-stranded cable
Colours: grey, blue, green, red and yellow
½m, 1m, 3m and 5m lengths available from stock
Highly flexible Jacket: 0.453mm 75°C PVC
Insulation: 0.153mm polyolefin Stranded copper conductor
Unshielded 8P8C Plugs
Meets all requirements for Gigabit Ethernet
ISO/IEC 11801 transmission requirement for stranded wire
UL, CSA & ETL verified
Tested and verified to TIA/EIA -568-B.2-1
Moulded strain-relief boots 50 micron gold plated
RJ45 connector Individually packed in Poly bag
Suitable for high density
Blade Network equipment
GIGANET CAT 6A F/UTP 3M PATCHCORD
Key features;
- Cable Type: Cat6A UTP (Unshielded Twisted Pair)
- Cable Length: 3 meters (9.84 feet)
- Cable Color: Varies (typically blue, gray, or black)
- Conductor Type: Copper
- Conductor Gauge: 24 AWG (American Wire Gauge)
- Transmission Speed: Up to 10 Gigabit Ethernet
- Frequency Bandwidth: Up to 500 MHz
- Wiring Standard: TIA/EIA-568-B
- Connector Type: RJ45 (8P8C) on both ends